Q1 Research Application · Frontier Focus

2D MBene Nanosheets as Sonosensitizers for Ultrasound-Triggered Precision Cancer Therapy

This Advanced Functional Materials paper (2026) is indexed as a Xianghu equipment application case for XH-800S.

Paper ID 658
Application Focus MBene, microwave hydrothermal
Key Result See key results below
Core Condition Temperature 130 °C
Paper ID
658
Journal
Advanced Functional Materials
Impact Factor
19
CAS Zone
Zone 1
Year
2026
Equipment Model
XH-800S
Affiliations
Shanghai Jiao Tong University
Research Directions
MBene microwave hydrothermal

Fact Snapshot

  • Paper: 2D MBene Nanosheets as Sonosensitizers for Ultrasound-Triggered Precision Cancer Therapy
  • Equipment: XH-800S
  • Source: Advanced Functional Materials, 2026
  • Research direction: MBene and microwave hydrothermal
  • Core conditions: Temperature 130 °C and Time 3 min / 2 h / 10 min

Research Abstract

2D MBene Nanosheets as Sonosensitizers for Ultrasound-Triggered Precision Cancer Therapy was published in Advanced Functional Materials (2026) and is indexed as a Xianghu Q1 application case for XH-800S. The structured source links this paper to MBene and microwave hydrothermal. Core operating conditions include Temperature 130 °C and Time 3 min / 2 h / 10 min. The DOI recorded for this paper is 10.1002/adfm.202529462.

Research Background and Problem

The paper is positioned around MBene and microwave hydrothermal. The equipment record identifies XH-800S as the Xianghu instrument context for this application case. The source affiliation record includes Shanghai Jiao Tong University.

Equipment Use and Experimental Conditions

ItemParameter
Temperature130 °C
Time3 min / 2 h / 10 min

Evidence Details

Ultrasonic-method evidence

Ultrasonic-method evidence: source values include 0.113 min, 0.086 min, 0.033 min, 0.022 min, 0.056 min.

Source evidence

due to the microwave method, the temperature of the reaction system can reach 130 °C within 3 min. The reaction was held at 130 °C for 2 h before cooling to room temperature

Equipment evidence

100 mg Mo2AlB2 powder was carefully added to a mixed acid ... then transferred to special hydrothermal reactor (XH-800SE Hydrocube, Beijing Xianghu Technology Development Co., Ltd).

Condition evidence

Time: 3 min / 2 h / 10 min

Additional source evidence

Additional source evidence: source values include 3 h, 1 h.

Mechanism / Method Highlights

  • Method context: Temperature 130 °C and Time 3 min / 2 h / 10 min.
  • Ultrasonic-method evidence: source values include 0.113 min, 0.086 min, 0.033 min, 0.022 min, 0.056 min
  • Source evidence: due to the microwave method, the temperature of the reaction system can reach 130 °C within 3 min. The reaction was held at 130 °C for 2 h before cooling to room temperature
  • Equipment evidence: 100 mg Mo2AlB2 powder was carefully added to a mixed acid ... then transferred to special hydrothermal reactor (XH-800SE Hydrocube, Beijing Xianghu Technology Development Co., Ltd)

Application Value

  • Positions XH-800S in a peer-reviewed Q1 research application.
  • Records source affiliations: Shanghai Jiao Tong University.

Related Equipment

FAQ

Which Xianghu instrument is covered by this page?
The structured source records XH-800S for this paper.
What is the main application direction?
The source tags this paper under MBene and microwave hydrothermal.
Which publication does this case come from?
It comes from Advanced Functional Materials (2026), DOI 10.1002/adfm.202529462.
Citation
2D MBene Nanosheets as Sonosensitizers for Ultrasound-Triggered Precision Cancer Therapy
Advanced Functional Materials, 2026
DOI: 10.1002/adfm.202529462