Fact Snapshot
- Paper: 2D MBene Nanosheets as Sonosensitizers for Ultrasound-Triggered Precision Cancer Therapy
- Equipment: XH-800S
- Source: Advanced Functional Materials, 2026
- Research direction: MBene and microwave hydrothermal
- Core conditions: Temperature 130 °C and Time 3 min / 2 h / 10 min
Research Abstract
2D MBene Nanosheets as Sonosensitizers for Ultrasound-Triggered Precision Cancer Therapy was published in Advanced Functional Materials (2026) and is indexed as a Xianghu Q1 application case for XH-800S. The structured source links this paper to MBene and microwave hydrothermal. Core operating conditions include Temperature 130 °C and Time 3 min / 2 h / 10 min. The DOI recorded for this paper is 10.1002/adfm.202529462.
Research Background and Problem
Equipment Use and Experimental Conditions
| Item | Parameter |
|---|---|
| Temperature | 130 °C |
| Time | 3 min / 2 h / 10 min |
Evidence Details
Ultrasonic-method evidence: source values include 0.113 min, 0.086 min, 0.033 min, 0.022 min, 0.056 min.
due to the microwave method, the temperature of the reaction system can reach 130 °C within 3 min. The reaction was held at 130 °C for 2 h before cooling to room temperature
100 mg Mo2AlB2 powder was carefully added to a mixed acid ... then transferred to special hydrothermal reactor (XH-800SE Hydrocube, Beijing Xianghu Technology Development Co., Ltd).
Time: 3 min / 2 h / 10 min
Additional source evidence: source values include 3 h, 1 h.
Mechanism / Method Highlights
- Method context: Temperature 130 °C and Time 3 min / 2 h / 10 min.
- Ultrasonic-method evidence: source values include 0.113 min, 0.086 min, 0.033 min, 0.022 min, 0.056 min
- Source evidence: due to the microwave method, the temperature of the reaction system can reach 130 °C within 3 min. The reaction was held at 130 °C for 2 h before cooling to room temperature
- Equipment evidence: 100 mg Mo2AlB2 powder was carefully added to a mixed acid ... then transferred to special hydrothermal reactor (XH-800SE Hydrocube, Beijing Xianghu Technology Development Co., Ltd)
Application Value
- Positions XH-800S in a peer-reviewed Q1 research application.
- Records source affiliations: Shanghai Jiao Tong University.
Related Equipment
FAQ
Which Xianghu instrument is covered by this page?
What is the main application direction?
Which publication does this case come from?
2D MBene Nanosheets as Sonosensitizers for Ultrasound-Triggered Precision Cancer Therapy
Advanced Functional Materials, 2026
DOI: 10.1002/adfm.202529462