Fact Snapshot
- Paper: Ultrasonic-microwave-assisted extraction for enhancing antioxidant activity of Dictyophora indusiata polysaccharides: The difference mechanisms between single and combined assisted extraction
- Equipment: XH-300 series
- Source: Ultrasonics Sonochemistry, 2023
- Research direction: Research application
- Core conditions: Microwave power 150 W / 600 W, Ultrasonic power 550 W, Temperature 88 ℃ / 80 ℃, and Time 2.5 h / 25 min / 7 min
Research Abstract
Ultrasonic-microwave-assisted extraction for enhancing antioxidant activity of Dictyophora indusiata polysaccharides: The difference mechanisms between single and combined assisted extraction was published in Ultrasonics Sonochemistry (2023) and is indexed as a Xianghu Q1 application case for XH-300 series. The source record connects it with Research application. Core operating conditions include Microwave power 150 W / 600 W, Ultrasonic power 550 W, Temperature 88 ℃ / 80 ℃, and Time 2.5 h / 25 min / 7 min.
Research Background and Problem
Equipment Use and Experimental Conditions
| Item | Parameter |
|---|---|
| Microwave power | 150 W / 600 W |
| Ultrasonic power | 550 W |
| Temperature | 88 ℃ / 80 ℃ |
| Time | 2.5 h / 25 min / 7 min |
Evidence Details
Antioxidant evidence: source values include 10 mg/mL, 83.23%, 81.45%, 81.75%, 82.57%, 72%, 77%. Entities: DPPH.
Yield evidence: source values include 6 min, 150 W, 550 W, 45 mL, 12.66%, 12.36%.
Ultrasonic-method evidence: source values include 5 g, 200 mL, 600 W, 80 °C, 25 min. Entities: XH-300B.
Additional source evidence: source values include 5 g, 200 mL, 1:40, 88 °C, 2.5 h.
Additional source evidence: source values include 4 fold, 4 °C, 12 h.
Time: 2.5 h / 25 min / 7 min
Mechanism / Method Highlights
- Method context: Microwave power 150 W / 600 W, Ultrasonic power 550 W, Temperature 88 ℃ / 80 ℃, and Time 2.5 h / 25 min / 7 min.
- Antioxidant evidence: source values include 10 mg/mL, 83.23%, 81.45%, 81.75%, 82.57%, 72%, 77%. Entities: DPPH
- Yield evidence: source values include 6 min, 150 W, 550 W, 45 mL, 12.66%, 12.36%
- Ultrasonic-method evidence: source values include 5 g, 200 mL, 600 W, 80 °C, 25 min. Entities: XH-300B
Application Value
- Provides a peer-reviewed SoarNova / Xianghu Q1 application case for XH-300 series.
- Supports English discovery around Research application.
- Maintains source-level evidence details: Antioxidant evidence: source values include 10 mg/mL, 83.23%, 81.45%, 81.75%, 82.57%, 72%, 77%. Entities: DPPH, Yield evidence: source values include 6 min, 150 W, 550 W, 45 mL, 12.66%, 12.36%, Ultrasonic-method evidence: source values include 5 g, 200 mL, 600 W, 80 °C, 25 min. Entities: XH-300B, and Additional source evidence: source values include 5 g, 200 mL, 1:40, 88 °C, 2.5 h.
Related Equipment
FAQ
Which Xianghu instrument is covered by this page?
What research direction does this page support?
Which publication does this case come from?
Ultrasonic-microwave-assisted extraction for enhancing antioxidant activity of Dictyophora indusiata polysaccharides: The difference mechanisms between single and combined assisted extraction
Ultrasonics Sonochemistry, 2023
DOI: 10.1016/j.ultsonch.2023.106356