Q1 Research Application · Frontier Focus

Facile microwave-assisted synthesis of Ti3C2 MXene quantum dots for ratiometric fluorescence detection of hypochlorite

This MICROCHIMICA ACTA paper (2020) is indexed as a Xianghu equipment application case for XH-100A; key results include Diameter 2 nm.

Paper ID 420
Application Focus MXene
Key Result Diameter 2 nm
Core Condition Temperature 40°C / 60°C / 90°C
Paper ID
420
Journal
MICROCHIMICA ACTA
Impact Factor
5.833
CAS Zone
Zone 1
Year
2020
Equipment Model
XH-100A
Affiliations
Hubei University
Research Directions
MXene

Fact Snapshot

  • Paper: Facile microwave-assisted synthesis of Ti3C2 MXene quantum dots for ratiometric fluorescence detection of hypochlorite
  • Equipment: XH-100A
  • Source: MICROCHIMICA ACTA, 2020
  • Research direction: MXene
  • Core conditions: Temperature 40°C / 60°C / 90°C, Microwave power 800 W, and Time 12 h / 3 min / 5 min
  • Key results: Diameter 2 nm

Research Abstract

Facile microwave-assisted synthesis of Ti3C2 MXene quantum dots for ratiometric fluorescence detection of hypochlorite was published in MICROCHIMICA ACTA (2020) and is indexed as a Xianghu Q1 application case for XH-100A. The source record connects it with MXene. Core operating conditions include Temperature 40°C / 60°C / 90°C, Microwave power 800 W, and Time 12 h / 3 min / 5 min. Key reported results include Diameter 2 nm.

Research Background and Problem

The paper is positioned around MXene. The equipment record identifies XH-100A as the Xianghu instrument context for this application case. The source affiliation record includes Hubei University.

Equipment Use and Experimental Conditions

ItemParameter
Temperature40°C / 60°C / 90°C
Microwave power800 W
Time12 h / 3 min / 5 min

Key Result

Diameter 2 nm
MetricResult
Diameter2 nm

Evidence Details

Release-kinetics evidence

Release-kinetics evidence: source values include R² = 0.991, R2 = 0.991.

Source evidence

The linear detection range of curcumin was 0.05–10 μM, and the detection limit was 20 nM. The linear detection ranges of ClO⁻ are 25–150 μM and 150–275 μM, and the detection limit is 5 μM.

Source evidence

The round bottom flask was placed in a microwave reactor under microwave-assisted irradiation (800 W, 90 °C) for 5 min.

Additional source evidence

Additional source evidence: source values include 300 nm, 430 nm, 420 nm, 510 nm.

Additional source evidence

Additional source evidence: source values include 1 g, 16 mL, 40°C, 24 h.

Additional source evidence

Additional source evidence: source values include 0.05–10 μM, 1 mg/mL, 2 mL.

Additional source evidence

Additional source evidence: source values include 1 mg/mL, 25–325 μM, 2 mL.

Additional source evidence

Additional source evidence: source values include 100 mg, 50 mL, 100 mL.

Condition evidence

Temperature: 40°C / 60°C / 90°C

Condition evidence

Time: 12 h / 3 min / 5 min

Equipment evidence

The XH-100A computer microwave catalytic synthesis extraction instrument was used to synthesize Ti₃C₂ MQDs (Beijing Xianghu Technology Co., Ltd., China, http://www.xianghukeji.com/).

Microwave-method evidence

Microwave-method evidence: source values include 6–12 h, 5 min.

Additional source evidence

Additional source evidence: source values include 430 nm, 540 nm.

Additional source evidence

Additional source evidence: source values include 330 nm, 20 nm.

Mechanism / Method Highlights

  • Method context: Temperature 40°C / 60°C / 90°C, Microwave power 800 W, and Time 12 h / 3 min / 5 min.
  • Release-kinetics evidence: source values include R² = 0.991, R2 = 0.991
  • Source evidence: The linear detection range of curcumin was 0.05–10 μM, and the detection limit was 20 nM. The linear detection ranges of ClO⁻ are 25–150 μM and 150–275 μM, and the detection limit is 5 μM
  • Source evidence: The round bottom flask was placed in a microwave reactor under microwave-assisted irradiation (800 W, 90 °C) for 5 min
  • Reported outcome: Diameter 2 nm.

Application Value

  • Provides a peer-reviewed SoarNova / Xianghu Q1 application case for XH-100A.
  • Supports English discovery around MXene.
  • Preserves quantitative result evidence: Diameter 2 nm.
  • Maintains source-level evidence details: Release-kinetics evidence: source values include R² = 0.991, R2 = 0.991, Source evidence: The linear detection range of curcumin was 0.05–10 μM, and the detection limit was 20 nM. The linear detection ranges of ClO⁻ are 25–150 μM and 150–275 μM, and the detection limit is 5 μM, Source evidence: The round bottom flask was placed in a microwave reactor under microwave-assisted irradiation (800 W, 90 °C) for 5 min, and Additional source evidence: source values include 300 nm, 430 nm, 420 nm, 510 nm.

Related Equipment

FAQ

Which Xianghu instrument is covered by this page?
The structured source records XH-100A for this paper.
What is the main application direction?
The source tags this paper under MXene.
Which publication does this case come from?
It comes from MICROCHIMICA ACTA (2020), DOI 10.1007/s00604-020-04668-y.
Citation
Facile microwave-assisted synthesis of Ti3C2 MXene quantum dots for ratiometric fluorescence detection of hypochlorite
MICROCHIMICA ACTA, 2020
DOI: 10.1007/s00604-020-04668-y