Fact Snapshot
- Paper: Impact of combined ultrasound-microwave treatment on structural and functional properties of golden threadfin bream (Nemipterus virgatus) myofibrillar proteins and hydrolysates
- Equipment: XH-300 series
- Source: Ultrasonics - Sonochemistry, 2020
- Research direction: enzymatic hydrolysis
- Core conditions: Temperature 51 °C, Ultrasonic power 400 W / 300 W / 100 W, and Microwave power 300 W / 100 W / 400 W
Research Abstract
Impact of combined ultrasound-microwave treatment on structural and functional properties of golden threadfin bream (Nemipterus virgatus) myofibrillar proteins and hydrolysates was published in Ultrasonics - Sonochemistry (2020) and is indexed as a Xianghu Q1 application case for XH-300 series. The structured source links this paper to enzymatic hydrolysis. Core operating conditions include Temperature 51 °C, Ultrasonic power 400 W / 300 W / 100 W, and Microwave power 300 W / 100 W / 400 W. The DOI recorded for this paper is 10.1016/j.ultsonch.2020.105063.
Research Background and Problem
Equipment Use and Experimental Conditions
| Item | Parameter |
|---|---|
| Temperature | 51 °C |
| Ultrasonic power | 400 W / 300 W / 100 W |
| Microwave power | 300 W / 100 W / 400 W |
| Power | 300 W |
| Time | 8 min |
Evidence Details
treated with 100 W microwave and varied ultrasonic power (100, 200, 300 and 400 W) until the temperature was 51 °C, then followed by preservation at 51 °C for 8 min
An XH-300B UM reactor ... was used to sonicate 150 mL of MP suspension (6 mg/mL) each time.
Ultrasonic-method evidence: source values include 100 W, 300 W. Entities: XH-300B.
Cell viabilities was increased above 90% when damaged cells were treated with 6 mg/mL sample produced by U300-M100 method.
U300-M100 presented the smallest double-dispersed population, with sizes of 14.55 nm and 53.32 nm, respectively.
The solubility of U300-M100 products ranged from 83−100% at pH 2–10
Additional source evidence: source values include 16.95 ± 0.5%, 4.89 ± 0.21 mg/mL. Entities: U300-M100.
Additional source evidence: source values include 16.89 ± 0.95%, 4.66 ± 0.78 mg/mL.
Additional source evidence: source values include 17.32 ± 0.40%, 4.78 ± 1.07 mg/mL.
Additional source evidence: source values include 83-100%. Entities: U300-M100.
Mechanism / Method Highlights
- Method context: Temperature 51 °C, Ultrasonic power 400 W / 300 W / 100 W, Microwave power 300 W / 100 W / 400 W, and Power 300 W.
- Equipment evidence: treated with 100 W microwave and varied ultrasonic power (100, 200, 300 and 400 W) until the temperature was 51 °C, then followed by preservation at 51 °C for 8 min
- Equipment evidence: An XH-300B UM reactor ... was used to sonicate 150 mL of MP suspension (6 mg/mL) each time
- Ultrasonic-method evidence: source values include 100 W, 300 W. Entities: XH-300B
Application Value
- Positions XH-300 series in a peer-reviewed Q1 research application.
- Records source affiliations: Fujian University of Agriculture and Forestry.
Related Equipment
FAQ
Which Xianghu instrument is covered by this page?
What is the main application direction?
Which publication does this case come from?
Impact of combined ultrasound-microwave treatment on structural and functional properties of golden threadfin bream (Nemipterus virgatus) myofibrillar proteins and hydrolysates
Ultrasonics - Sonochemistry, 2020
DOI: 10.1016/j.ultsonch.2020.105063